{"created":"2023-06-20T13:11:31.627289+00:00","id":736,"links":{},"metadata":{"_buckets":{"deposit":"723824f6-b8a6-44e2-8c82-ea3978286352"},"_deposit":{"created_by":15,"id":"736","owners":[15],"pid":{"revision_id":0,"type":"depid","value":"736"},"status":"published"},"_oai":{"id":"oai:tohoku-mpu.repo.nii.ac.jp:00000736","sets":["3:69"]},"author_link":[],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"64","bibliographicPageEnd":"81","bibliographicPageStart":"77","bibliographic_titles":[{"bibliographic_title":"東北医科薬科大学研究誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"Journal of Tohoku Medical and Pharmaceutical University","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"in order to make drug preparation procedures more efficient, pharmacists need to carefully consider each step of the process. For example, when using a syringe to collect a precise volume of liquid from an injection bag, the air previously in the syringe needs to be removed. Therefore, we compared methods to remove the air from a syringe before and after withdrawing liquid from an injection bag. The volume of injection liquid in the syringe and the time required to perform both methods were compared using results obtained from fourth-year students (with only university training to mix injection preparations), fifth-year students(with 11 weeks of pharmacy practice training in a hospital), and hospital pharmacists. Two types of syringes(5 and 10 mL)were used in this study. The volumes of liquid collected were 2 mL(5-mL syringe)and 5 mL(10-mL syringe).\nNo significant differences were observed in operation times or syringe liquid volumes between the both methods performed by fourth-year students. Operation times were significantly shorter with the removal of air from the syringe before withdrawing the injection liquid than with that after withdrawing the injection liquid when performed by fifthyear students and hospital pharmacists; however, no significant differences were observed in syringe liquid volumes.\nThese results demonstrate that the method involving the removal of air from the syringe before withdrawing the liquid is useful for reducing operation times for the collection of a precise volume of liquid from an injection bag with a syringe when fifth-year students or pharmacists perform the mixing procedures for injections.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"東北医科薬科大学","subitem_publisher_language":"ja"}]},"item_10002_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Attribution-NonCommercial-NoDerivs 3.0 Unported (CC BY-NC-ND 3.0)","subitem_rights_language":"en","subitem_rights_resource":"https://creativecommons.org/licenses/by-nc-nd/3.0/deed.en"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2432-5724","subitem_source_identifier_type":"PISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小嶋, 文良","creatorNameLang":"ja"},{"creatorName":"オジマ, フミヨシ","creatorNameLang":"ja-Kana"},{"creatorName":"Ojima, Fumiyoshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"小池, 猶土","creatorNameLang":"ja"},{"creatorName":"コイケ, ユウト","creatorNameLang":"ja-Kana"},{"creatorName":"Koike, Yuto","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"大成権, 和志","creatorNameLang":"ja"},{"creatorName":"ダイジョウゴン, カズシ","creatorNameLang":"ja-Kana"},{"creatorName":"Daijogon, Kazushi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"神谷, 貞弘","creatorNameLang":"ja"},{"creatorName":"カミヤ, サダヒロ","creatorNameLang":"ja-Kana"},{"creatorName":"Kamiya, Sadahiro","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"三浦, 剛","creatorNameLang":"ja"},{"creatorName":"ミウラ, ゴウ","creatorNameLang":"ja-Kana"},{"creatorName":"Miura, Go","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"伊庭, 照枝","creatorNameLang":"ja"},{"creatorName":"イバ, テルエ","creatorNameLang":"ja-Kana"},{"creatorName":"Iba, Terue","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"高橋, 佐和士","creatorNameLang":"ja"},{"creatorName":"タカハシ, サトシ","creatorNameLang":"ja-Kana"},{"creatorName":"Takahashi, Satoshi","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-12-06"}],"displaytype":"detail","filename":"原著3_小嶋文良.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"正確な注射液量を採取する効率的な方法の検討 ── 液を採取する前に空気を抜くBefore withdrawing 法と液を採取後に空気を抜くAfter withdrawing 法の比較──","objectType":"fulltext","url":"https://tohoku-mpu.repo.nii.ac.jp/record/736/files/原著3_小嶋文良.pdf"},"version_id":"92e722de-b32f-4a6c-aac5-72ced3292648"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"injections","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"injection mixing maneuver","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"operation time","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"precise volume","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"syringe","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"正確な注射液量を採取する効率的な方法の検討 ── 液を採取する前に空気を抜くBefore withdrawing 法と液を採取後に空気を抜くAfter withdrawing 法の比較──","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"正確な注射液量を採取する効率的な方法の検討 ── 液を採取する前に空気を抜くBefore withdrawing 法と液を採取後に空気を抜くAfter withdrawing 法の比較──","subitem_title_language":"ja"},{"subitem_title":"Investigation of an Efficient Method for Collecting Precise Volume of Injection Liquid; ── Comparison of Methods to Remove Air before(Before Withdrawing Method)and after(After Withdrawing Method)Collecting Liquid with the Syringe Barrel ──","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"15","path":["69"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-12-06"},"publish_date":"2018-12-06","publish_status":"0","recid":"736","relation_version_is_last":true,"title":["正確な注射液量を採取する効率的な方法の検討 ── 液を採取する前に空気を抜くBefore withdrawing 法と液を採取後に空気を抜くAfter withdrawing 法の比較──"],"weko_creator_id":"15","weko_shared_id":-1},"updated":"2024-03-03T23:41:35.335811+00:00"}